Continental Hydraulics UK Ltd
Relentless Power and Performance
 

 

HPV

HPV

HPV

HPV

HPV Series Axial Piston Pumps

FEATURES & BENEFITS

  • QUIET OPERATION

Combining new technology, strict engineering disciplines and efficiently designed porting has reduced noise to very low levels.

  • SIMPLE CONSTRUCTION

For a long and productive life.

  • APPLICATION FLEXABILTY

Four pump controls, Tandem pump options for multiple pump applications; high speed operation for mobile applications, maximum volume control is standard for application versatility.

  • RUGGED CONSTRUCTION

Heavy duty cylinder block and body castings provide long life and reduced noise, hardened swash plate for extended trunnion life.

  • COMPACT SIZE

Designed to maximize the use of valuable space.

  • MAXIMUM VOLUME ADJUSTMENT

Allows you to set the pump displacement to match the maximum system flow requirements and prevents overloading of the system.

  • DESIGNED TO BE REBUILDABLE

Great care was taken in the design of this pump to ensure that when it is in need of service, it can be disassembled and brought back into service with replaceable port and wear plates, simplifying maintenance.

 

Model Series
Max Continuous Pressure
Volumetric Displacement CC/Rev
Theoretical Flow @ 1450 RPM
Mounting Flange
HPV-6B35
3500 PSI
14.4
20.88 Lit/Min
SAE. A 2 Bolt
HPV-10B35
3500 PSI
21.1
30.60 Lit/Min
SAE. B 2 Bolt
HPV-15B35
3500 PSI
34.2
49.60 Lit/Min
SAE. B 2 Bolt
HPV-20B35
3500 PSI
42.9
62.20 Lit/Min
SAE. C 2 Bolt
HPV-29B35
3000 PSI
61.9
89.70 Lit/Min
SAE. C 2 Bolt

 

Piston Pump Specifications (1.83 MB) PDF...

 

 

 

CONTROL OPTIONS

STANDARD PRESSURE COMPENSATED

Delivers only the flow required by the system, while maintaining the set pressure. This will save horsepower and unnecessary wear on the system.

Pressure compensation ranges from 200 to 3500 PSI continuous duty and up to 4000 PSI intermittently.

REMOTE PRESSURE CONTROL: MODEL CODE 7

Includes all the features of the standard pressure compensator with the added feature of remote control. This option allows you to adjust or vent the pump control from a remote location for multiple pressure operations.

LOAD SENSING CONTROL: MODEL CODE 19

Provides constant flow through a given orifice and pressure that varies with the load requirements. This control maximizes efficiency and minimizes heat generation.

HORSEPOWER LIMITING CONTROL: MODEL CODE 26

This control is highly recommended where high pressures - low flows, and high flows - low pressures are needed.

Control Option Specifications - Page 5 to 8 (Piston Pump PDF)...

GENERAL SPECIFICATIONS

  • Recommended Fluids

Fluids for use in the HPV series piston pumps should be petroleum based and designated by the fluid manufacturer for use in hydraulic systems. These fluids should contain rust and oxidation inhibition, anti-wear, anti-foam, and de-aerating agents. For other fluid types, please contact your Continental Application Engineer.

  • Recommended Operating Viscosities

For petroleum based fluids:

    • Optimum -- 140 sus (30 Cst.).
    • Continuous Minimum -- 60 sus (10 Cst.).
    • Continuous Maximum -- 750 sus (160 Cst.).

     

  • Operating Temperature

The operating temperature should be determined by the viscosity characteristics of the fluid used. Because high temperatures degrade seals, reduce the service life of the fluid, and create hazards, fluid temperatures should not exceed 180° F. (82° C.) at the case drain.

  • Fluid Cleanliness

ISO 16/13.

  • Filtration

Return line: To maintain the minimum prescribed cleanliness levels, a high quality return line filter should be used. A filter with a 10 micron rating is normally sufficient to start up a system. Because every system has unique characteristics, this rating may need to be changed. Periodic testing of fluid is highly recommended. The data collected from these tests will tell if the current filter system is maintaining the cleanliness of the fluid to the ISO 16/13 level.

  • Maximum Inlet Pressure

The maximum inlet pressure is 50 PSI at all speeds.

  • Mounting Position

Unrestricted, however horizontal mounting is preferred.

  • Drive Shaft Alignment

Pump and motor must be within .003 inches (0.8 mm) TIR (Total Indicated Run out) for maximum bearing life.

  • Drive Coupling

Jaw type with a flexible web is recommended.

Tire and Chain type couplings are not recommended.

  • Case Drain

All HPV series piston pumps have two case drain ports. It is only necessary to connect a case drain line to one of these ports. The other port is provided to fill the case with fluid on start up. All case drain lines should be as short as possible with no restrictions or reduction in size. The routing of the case drain line back to the reservoir must not allow the fluid in the case to drain back into the reservoir while the pump is not in use. This line should terminate below the surface of the fluid in the reservoir. Please refer to Continental Hydraulics HPV series installation and service literature for further explanation. Relief Valves System relief valves are recommended for all applications to protect personnel and the system from potentially damaging overloads. These valves should be sized for the maximum flow of the pump and set approximately 200 psi above the pump compensator setting.

 

Continental Hydraulics

Continental Hydraulics.

 

Rhino

 

Piston Pump Specifications (1.83 MB) PDF...

HPV Group Photo...

HPV Guide to replacing Denison PV series pumps...

 
 

 

Home Page | Contact Us | Site Map | Terms & Conditions | Phone: 08450 043440

Copyright © 2006 Continental Hydraulics UK Ltd. All rights reserved. Registered in England No 5711867